Horizontal self-cleaning filter - HBE

We'll help you choose the right solution! Contact us!
Request a quote

Description

Horizontal self-cleaning filters - HBE/CHBE are electronically controlled filters with fully automatic backwash systems.

The backwash process needs no additional energy, as it uses the kinetic energy of the water.

However, to detect filter clogging and start the backwash, the electronic control unit is powered by an internal battery.

Using the water pressure supplied by the pump, a fully automatic backwash is performed and all filtering elements are cleaned automatically.

While the backwash mechanism is running, water filtration continues.

The dirty backwash water is discharged automatically.

For these reasons, the HBE series and the stainless steel CHBE models are fully automatic water filters, faster and more efficient than manual and/or semi-automatic self-cleaning systems.

In addition, HBE / CHBE filters reduce backwash time and water consumption.

Image gallery

General features

Housing material: S235JR / SS304L / SS316L;
Screen material: SS 304L, PA6GFR30;
Maximum working pressure: 10 bar (145 psi), up to 16 bar on request;
Minimum working pressure: 2.5 bar (36 psi);
Maximum working temperature: 60 °C (140 °F);
Backwash criteria: time and/or differential pressure;
Backwash control unit: electronic control (AC/DC);
Filtration degree: 20–2000 micron (µ);
Painting method: electrostatic powder coating;
Paint material: epoxy polyester.

Drawings and charts

Operating principle:

Water entering the filter passes through the coarse screen and then reaches the fine screen. From there it flows through the fine screen to the outlet, from inside to outside, so the filtered sediment builds up on the inside of the fine screen and causes a pressure drop between inlet and outlet. When this differential pressure reaches a preset value (recommended 0.5 bar), the self-cleaning process starts and the control unit opens the flush valve.

The difference between the inlet pressure and the pressure after the flush valve (atmospheric pressure) creates strong suction (vacuum) at the cleaning nozzles, which removes the sediment from the inside of the screen. The cleaning collector rotates, and the dirty water is discharged from the cleaning collector through the hydraulic turbine and then through the drain line.

In the turbine chamber, the piston and piston rod also give the cleaning collector a linear motion.

The rotation and linear motion let the nozzles suck the layer of contaminants from the entire inner surface of the screen.

When the process is complete, the cleaning collector automatically returns to its initial position and the backwash ends. Water filtration is not interrupted during backwash.

For efficient operation, the water inlet pressure must not drop below 2 bar (29 psi) during flushing.

Product codeHBE/CHBE104HBE/CHBE104SHBE/CHBE105HBE/CHBE105SHBE/CHBE106HBE/CHBE126SHBE/CHBE128HBE/CHBE1210
INLET/
OUTLET
inch445566810
DN100100125125150150200250
A (mm)500600600900900110011001100
B (mm)287287287287287312312312
L1 (mm)10711274127415651565195419541954
L (mm)15101710171020202020241024102410
D (inch)1010101010121212
F (inch)22222222
Drain flow
(m³/h)
11,914,814,8181823,823,823,8
Flow (m³/h)120140150160180220320380
Filtration area (cm²)26343951395152685268790279027902
Nozzles
(pcs)
23344666
Screens
(pcs)
46688121212
Weight (kg)6475788994132135166