Aytok P20 plastic hydrocyclone filters protect filtration systems through pre-filtration: they separate sand and particles heavier than water before the main filters.
They are generally used where the water is heavily polluted.
For higher flow rates or more heavily loaded water, several hydrocyclones are installed in parallel.
Housing material: PA6GFR30;
Maximum working pressure: 6 bar (87 psi);
Maximum working temperature: 60 °C (140 °F);
Minimum flow rate: P2010: 3 m³/h; P2020: 15 m³/h; P2025: 20 m³/h; P2030: 25 m³/h.
Hydrocyclone filters have a simple design and are used to filter well water or water containing sand, gravel and particles heavier than water.
They are frequently used in agricultural irrigation as the first water filtration stage.
Hydrocyclone filters operate at maximum efficiency with minimal pressure loss in irrigation systems.
Water enters the conical body tangentially and forms a vortex; centrifugal force pushes the heavy particles towards the wall, from where they drop into the sand tank, while the clean water leaves through the centre, at the top. The filter has no moving parts and no filter media.
Solid particles heavier than water slide down through the narrower, conical part of the hydrocyclone and are collected in the waste chamber (sand tank).
The clean water, separated from the solid particles, leaves through the outlet pipe.
The accumulated sediment is periodically discharged from the sand tank through the purge valve, manually or automatically with a controller.
When connecting the filter, the “inlet” / “outlet” ends must be observed.
| Product code | P2010 | P2020 | P2025 | P2030 |
|---|---|---|---|---|
| D (inch / DN) | 1 / 25 | 2 / 50 | 2½ / 65 | 3 / 80 |
| T (inch) | 1/2 | 3/4 | 3/4 | 2 |
| H (mm) | 390 | 1025 | 1025 | 1225 |
| H1 (mm) | 448 | 1154 | 1154 | 1360 |
| L (mm) | 255 | 580 | 580 | 670 |
| W (mm) | 113 | 206 | 206 | 322 |
| Flow (m³/h) | 5-10 | 20-30 | 30-40 | 40-60 |
| Weight (kg) | 1,9 | 9,5 | 9,5 | 19 |