Vertical self-cleaning filter with gear motor - VRF

We'll help you choose the right solution! Contact us!
Request a quote

Description

VRF/CVRF vertical self-cleaning filters with gear motor are filters in which the collector pipe is moved by an electric gear motor and the dirty water is discharged through a motorized valve. These filters perform self-cleaning and can operate on 220 V and 380 V alternating current.

The ΔP (differential pressure) sensor is used by the electronic control unit to detect how loaded the filter is with impurities and to start self-cleaning.

The opening of the motorized valve, controlled by the control unit, together with the forward and backward movement and rotation driven by the gear motor, removes and flushes out the particles from the inner surface of the screen.

When the gear motor completes its cycle, the motorized valve closes and the process is complete. While the backwash mechanism is operating, water filtration is not interrupted.

The dirty water from this process is discharged automatically during backwashing.

Image gallery

General features

Body material: S235JR / SS304L / SS316L;
Screen material: SS 304L, PA6GFR30;
Maximum working pressure: 10 bar (145 psi), up to 16 bar on request;
Minimum working pressure: 1 bar (14.5 psi);
Maximum working temperature: 60 °C (140 °F);
Backwash criteria: time and/or differential pressure;
Backwash control unit: electronic control (AC);
Filtration degree: 20–2000 micron (µ);
Painting method: electrostatic powder coating;
Paint material: epoxy polyester.

Drawings and charts

Operating principle

Water entering the filter passes first through the coarse screen (pre-filtration), then through the fine screen, from inside to outside, and reaches the outlet. Sediment builds up on the inside of the fine screen, creating a pressure difference between inlet and outlet. When this difference reaches the preset level, or when the set time interval expires, the control unit opens the motorized drain valve.

The difference between the inlet pressure and the pressure after the drain valve (atmospheric pressure) creates strong suction (vacuum) at the cleaning collector and nozzles, which draw off the sediment retained on the screen and discharge it through the drain pipe.

The AC electric gear motor rotates the cleaning collector and moves it linearly forward and back; adjustable position sensors limit the stroke, so the nozzles scan and clean the whole screen surface.

When the gear motor completes its cycle, the motorized valve closes and the cleaning process is complete.

During backwashing, water filtration is not interrupted.

The filter cleans itself even at low inlet pressures, from 1 bar (14.5 psi).

Product codeVRF/CVRF102FVRF/CVRF1025FVRF/CVRF102VRF/CVRF1025VRF/CVRF103VRF/CVRF103SVRF/CVRF104VRF/CVRF104SVRF/CVRF105VRF/CVRF105SVRF/CVRF106
Inlet/Outlet
inch / DN
2 / 502½ / 652 / 502½ / 653 / 803 / 804 / 1004 / 1005 / 1255 / 1256 / 150
A (mm)310310390390390440440490690840840
B (mm)270270270270270270270270287287287
L1 (mm)20520536536536546546556588010801080
L (mm)10221022118211821182128212821432201222122212
D (inch)1010101010101010101010
F (inch)22222222222
Drain flow (m³/h)11,911,911,911,911,914,814,81814,81818
Flow (m³/h)304040505570100120150160180
Filtration area (cm²)658658131713171317197519752634395152685268
Nozzles (pcs)22222334344
Screens (pcs)11222334688
Weight (kg)272843444548505260132135